- Stripanels are available in 2 to 8 circuits.
- Color Coded.
- Stripanels can be wired and installed completely from front. Patented self-contained fastening device, “T-Nut”, is permanently attached, simplifies mounting, holds tight. patent No. 3046516.
- Thermocouple type and circuit numbers are marked on face of Stripanel. Stripanels are numbered starting from “1” unless specified otherwise.
- Stripanels are molded of glass filled thermoset compounds (will not melt) for high strength and dependability. The color coded panels will withstand ambient temperatures to 400°F (205°C) continuous and 500°F (260°C) intermittent. High-temperature panels (all Hi-Temp panels are color coded red will withstand ambient temperatures to 800°F (425°C) continuous and 1000°F (540°C) intermittent.
- 1211/1311 Mini 3-Pole Jacks slide and lock into stripanel frame.
Number of Circuits | "A" Dimension Panel OAL | "C" Dimension Cutout Length | Mini 3-Pole Panel Part No. | Hi-Temp Mini 3-Pole Panel Part No. |
---|---|---|---|---|
2 | 1 3/8" | 1 1/4" | 1437-2-(X) | 1537-2-(X) |
3 | 2 1/16" | 1 15/16" | 1437-3-(X) | 1537-3-(X) |
4 | 2 3/4" | 2 5/8" | 1437-4-(X) | 1537-4-(X) |
5 | 3 7/16" | 3 5/16" | 1437-5-(X) | 1537-5-(X) |
6 | 4 1/8" | 4" | 1437-6-(X) | 1537-6-(X) |
7 | 4 13/16" | 4 11/16" | 1437-7-(X) | 1537-7-(X) |
8 | 5 1/2" | 5 3/8" | 1437-8-(X) | 1537-8-(X) |
(X) = Thermocouple Type Code
TO ORDER:
- Give Stripanel No. [e.g. 1437]
- Specify Number of circuits [e.g. 1437-6]
- Specify Thermocouple Type [e.g. 1437-6-J]
- For vertical stripanels add suffix “V” [e.g. 1437-6-J-V]
- For Hi-Temp Stripanel [e.g. 1537-6-J]
For more information regarding Mini 3-PoleStripanels® – Catalog No. 1437
Consult your Marlin Catalog, Pages F-24 and F-25 .
Mini 3-Pole Stripanel® with Mounting Frame
Marlin Catalog No. 1438
- Stripanels with mounting frames can accommodate virtually any number of circuits.
- One-piece mounting frame is made of 3/32″ thick rigid steel with flat black finish.
- For specifications see Stripanel 1437 section.
- For frame sizes other than those specified, please consult the factory.
- Horizontal rows are assumed unless specified vertical by the suffix “V” which are numbered from top to bottom: e.g. 1438-4×12-48-K-V.
- Stripanels with mounting frames will withstand ambient temperatures of 400°F (205°C) continuous and 500°F (260°C) intermittent. Hi-Temp panels will withstand ambient temperatures to 800°F (425°C) continuous and 1000°F (540°C) intermittent.
TO ORDER:
- Give Stripanel No. [e.g. 1438]
- Specify Number of Horizontal Rows [e.g. 1438-4]
- Specify Number of Circuits per Row [e.g. 1438-4X12]
- Give Total Number of Circuits [e.g. 1438-4X12-48]
- Specify Thermocouple Type Code [e.g. 1438-4X12-48-K]
- For vertical rows add suffix “V” [e.g. 1438-4X12-48-K-V]
- For Hi-Temp Stripanel in Frame [e.g. 1538-4×12-48-K]
For more information regarding Mini 3-PoleStripanels® with Mounting Frame – Catalog No. 1438
Consult your Marlin Catalog, Page F-26.
19″ Rack – Mounted Stripanel® Mini 3-Pole
- Universal 19″ Rack accepts 2 to 24 Circuits of No. 1437 Stripanels.
- Circuits can be added in the field without changing frame.
- 19″ Rack Frame is made of sturdy 10 ga. steel that will not flex in use. Standard frame is flat black. High-Temperature frame is bright silver finish.
- Thermocouple type and circuit numbers are marked on the face of the Stripanel and polarity identification on the back. Stripanels are numbered starting with ‘1″ unless otherwise specified.
- Stripanels are molded of glass filled thermoset compounds (will not melt) for high strength and dependability. The color coded panels will withstand ambient temperatures to 400°F (205°C) continuous and 500°F (260°C) intermittent. High-temperature panels (ALL Hi-Temp panels are color coded red) will withstand ambient temperatures to 800°F (425°C) continuous and 1000°F (540°C) intermittent.
- For corrosive applications, gold plated inserts are available. Caution – system errors can result from use of plated contacts if significant thermal gradients exist at connector.
INSERT MATERIAL ALLOY T/C Type Code POSITIVE NEGATIVE GROUND ANSI COLOR CODE IEC
COLOR CODEJ IRON
CONSTANTAN COPPER BLACK BLACK T COPPER CONSTANTAN COPPER BLUE BROWN K CHROMELTM ALUMELTM COPPER YELLOW GREEN N NICROSIL NISIL COPPER ORANGE PINK R COPPER #11 Alloy COPPER GREEN ORANGE S COPPER #11 Alloy COPPER GREEN ORANGE E CHROMELTM
CONSTANTAN COPPER VIOLET VIOLET U COPPER COPPER COPPER WHITE WHITE C #426 Alloy #426 Alloy COPPER BROWN – 1,2,3 (2) Copper (3) Copper (1) Copper WHITE WHITE ALL HI-TEMP CONNECTORS RED RED
TO ORDER:
- Give Stripanel No. [e.g. 1441]
- Specify Number of Circuits [e.g. 1441-24]
- Specify Thermocouple Type Code [e.g. 1441-24-J]
- For Hi-Temp Stripanel” [e.g. 1441-24-J-]