Full-Size, 3-Pole Stripanels

Home Connectors and Stripanels Full-Size, 3-Pole Stripanels
Full-Size, 3-Pole Stripanels

Full Size, 3-Pole Stripanel® – Marlin Catalog No. 1034

  • Stripanels available in 2 to 12 circuits in even number of circuits
  • Color Coded
  • For cutouts – does not require mounting frame or holes.
    Stripanels can be wired and installed completely from front. Patented self-contained fastening device, “T-Nut”, is permanently attached, simplifies mounting, holds tight. Patent No. 3046516.
  • Thermocouple type and circuit numbers are marked on face of Stripanel and polarity identification on the back. Stripanels are numbered starting from “1” unless specified otherwise.
  • Stripanels are molded of glass filled thermoset compounds (will not melt) for high strength and dependability. The color coded panels will withstand ambient temperatures to 400°F (205°C) continuous and 500°F (260°C) intermittent. High-Temperature Panels (all Hi-Temp panels are color coded red) will withstand ambient temperatures to 800°F (425°C) continuous and 1000°F (540°C) intermittent.
  • Inserts are spring loaded collet type to assure positive full contact with the negative insert larger making it virtually impossible to mismate.
  • For corrosive applications, gold or nickel plated prongs and inserts are available. Caution – system errors can result from use of plated contacts if significant thermal gradients exist at connector.

TO ORDER:

  1. Give Stripanel No. [e.g. 1034]
  2. Specify Number of circuits [e.g. 1034-8]
  3. Specify Thermocouple Type by Code [e.g. 1034-8-J]
  4. For vertical rows add suffix “V” [e.g. 1034-8-J-V]
  5. For Hi-Temp Stripanel [e.g. 1134-8-J]
  6. Avaialability: J,K,T,N,E,R,S,U, also “C”
  7. Gold plated inserts are available. Use suffix “G” [e.g. 1034-8-J-G]
Number of Circuits"A" Dimension Panel Length"C" Dimension Cutout LengthFull Size
3-Pole Panel
Part No.
Hi-Temp Full Size
3-Pole Panel
Part No.
21 1/2"1 5/16"1034-2-*1134-2-*
43"2 13/16"1034-4-*1134-4-*
64 1/2"4 5/16"1034-6-*1134-6-*
86"5 13/16"1034-8-*1134-8-*
107 1/2"7 5/16"1034-10-*1134-10-*
129"8 13/16"1034-12-*1134-12-*

*Thermocouple Type Code: J,K,T,N,E,R,S, U,C

T/C TYPE CODEINSERT MAT'L ALLOYCOLOR CODE
POSITIVENEGATIVEGROUND
JIronConstantanCopperBlack
TCopperConstantanCopperBlue
KChromelTMAlumelTMCopperYellow
NNicrosilNisilCopperOrange
RCopper#11 AlloyCopperGreen
SCopper#11 AlloyCopperGreen
EChromelTMConstantanCopperViolet
UCopperCopperCopperWhite
C#405 Alloy#426 AlloyCopperBrown
ALL HI-TEMP CONNECTORSRed

For more information regarding Full Size – 3-Pole Stripanels® – Catalog No. 1034
Consult your Marlin Catalog.

Full Size – 3-Pole Stripanel® with Mounting Frame
Marlin Catalog No. 1035

  • Stripanels with mounting frames can accommodate virtually any number of circuits.
  • One-piece mounting frame is made of 3/32″ thick rigid steel with flat black finish.
  • For specifications see Stripanel 1034 section.
  • For available frame sizes, Please consult the factory.
  • Horoizontal rows are assumed unless specified vertical by the suffix “V” which are numbered from top to bottom: e.g. 1035 – 4×12 -48 -K – V.
  • Stripanels with mounting frames will withstand ambient temperatures of 400°F (205°C) continuous and 500°F (260°C) intermittent. Hi-Temp panels will withstand ambient temperatures to 800°F (425°C) continuous and 1000°F (540°C) intermittent.
  • For corrosive applications, gold or nickel plated prongs and inserts are available. Caution – system errors can result from use of plated contacts if significant thermal gradients exist at connector.

TO ORDER:

  • Give Stripanel No. [e.g. 1035]
  • Specify Number of Horizontal Rows [e.g. 1035-4]
  • Specify Number of Circuits per Row [e.g. 1035-4X10]
  • Give Total Number of Circuits [e.g. 1035-4X10-40]
  • Specify ANSI Thermocouple Code [e.g. 1035-4X10-40-J]
  • For Vertical rows add suffix “V” [e.g. 1035-4X10-40-J-V]
  • For Hi-Temp Stripanel in Frame [e.g. 1135-4×10-40-J-]
  • Availability: J,K,T,N,E,R,S,U,C
  • Gold plated inserts are available. Use suffix “G” [e.g. 1035-4×10-40-J-G]

For more information regarding Full Size – 3-Pole Stripanels® with Mounting Frame – Catalog No. 1035
Consult your Marlin Catalog.

FULL SIZE – 3-POLE – 19″ RACK – MOUNTED STRIPANEL®

  • Universal 19″ Racks accept 2 to 24 Circuits of No. 1034 Stripanels, less than 24 circuits are supplied with filler sections.
  • Circuits can be added in the field without changing frame.
  • 19″ Rack Frame is made of sturdy 10 ga. steel that will not flex in use. Standard frame is flat black. High-Temperature frame is bright silver finish.
  • Thermocouple type and circuit numbers are marked on the face of the stripanel and polarity identification on the back. Stripanels are numbered starting with “1” unless otherwise specified.
  • Stripanels are molded of glass filled thermoset compounds (will not melt) for high strength and dependability. The color coded panels will withstand ambient temperatures to 400°F (205°C) continuous and 500°F (260°C) intermittent. High-temperature panels (ALL Hi-Temp panels are color coded red) will withstand ambient temperatures to 800°F (425°C) continuous and 1000°F (540°C) intermittent.
  • Inserts are spring loaded collet type to assure positive full contact with the negative insert larger making it virtually impossible to mismate.
  • For corrosive applications, gold plated inserts are available. Caution – system errors can result from use of plated contacts if significant thermal gradients exist at connector.
T/C TYPE CODEINSERT MAT'L ALLOYCOLOR CODEHI-TEMP
COLOR CODE
POSITIVENEGATIVE
JIronConstantanBlackRed
TCopperConstantanBlueRed
KChromelTMAlumelTMYellowRed
NNicrosilNisilOrangeRed
RCopper#11 AlloyGreenRed
SCopper#11 AlloyGreenRed
EChromelTMConstantanVioletRed
UCopperCopperWhiteRed
C#405 Alloy#426 AlloyBrownRed

TO ORDER:

  • Give Code No. [e.g. 1042]
  • Specify Number of Circuits [e.g. 1042-24]
  • Specify ANSI Thermocouple Code [e.g. 1042-24-J]
  • For Hi-Temp Stripanel” [e.g. 1142-24-J]
  • Gold plated inserts are available. Use suffix “G” [e.g. 1042-24-J-G]

For more information regarding Full Size – 3-Pole – 19″ Rack – Mounted Stripanels® – Catalog No. 1042
Consult your Marlin Catalog

Products

  • Accessories
    • Instruments
    • Protecting Tubes
    • Thermowells
  • Connectors and Stripanels
  • Sensors
  • Thermocouple Wire
  • New Products
  • Obsolete Products
  • Catalog
Contact us today for a quote Contact

Temperature Instrumentation
for Research and Industry

© 2025 - Marlin Manufacturing | Powered by InUnison LTD

  • Home
  • Company Profile
  • Catalog
  • Products
    • Accessories
      • Instruments
      • Protecting Tubes
      • Thermowells
    • Connectors and Stripanels
    • Sensors
    • Thermocouple Wire
    • New Products
    • Obsolete Products
  • Quality
  • Metrology
  • Request A Quote
  • Contact Us