- 0.1°/1° Auto-Resolution
- °F/°C Switchable
- Compatible with Nine Temperature Sensor Types
- Switch Selectable (T/C and RTD)
- Repeatable to 1 Count
- Alarm Option
- Multi-Channel Option
Digital Indicators-Model 500-High Quality, Small Size, 1/8 DIN
The Model 500 is designed for a variety of temperature measuring applications. Excellent accuracy and its small size combine to make it the ideal choice for most industrial temperature indications.
The 500 features a unique 0.1° or 1° automatic resolution. For temperature measurements below 1000°, the instrument displays to a 0.1° resolution. Crossing over 1000°, the instrument automatically switches to a 1° resolution. Thermocouple types R, S and B only display in 1° increments. For any application where a 1° resolution is desired for everything, the unit can be set to display only 1° increments throughout its measuring range.
For ease of installation, each instrument is supplied in a standard 1/8 DIN (48 mm x 96 mm) plastic case and has rear-accessible universal screw terminals. Large LEDs make temperature readings easy to see and read, even from a distance. Power is derived from 115 or 230 VAC. Power is selectable via an internal slide switch.
Select between nine temperature sensors of thermocouple types J, K, T, E, R, S and B or 100 Ohm 3-wire, Platinum RTDs, either 0.00385 or 0.00392 alpha. Each of these nine are selected via a miniature rotary switch located directly behind the snap-off front lens. Another miniature DIP switch, also behind the lens, selects between °F or °C display.
Model 500 Options: The Model 500 accommodates one of two avaailable options. Either option can be specified at time of initial order or can be easily installed at some future date
Alarm Setpoint:
- The alarm option provides a single limit setpoint that can be set to any point, + or -, within the 500 measuring range. The user digitally sets the setpoint via two buttons located on the front panel.
- Selection of “HIGH” or “LOW” Alarm is set via a jump-jack located on the option card. Once the setpoint is set, it may be reviewed for its actual value by depressing the “view” button. A front panel LED illuminates when the alarm trips.
- The Alarm Setpoint option card also includes a Form C, 0.5A relay for hook-up to external lamps, buzzers or on/off control elements. Relay terminals are accessible at the rear of the instrument and provide hook-up for Normally Open or Normally Closed Operation.
Order Option: Model 500-ALM Multiple Inputs :
- The cost of measuring multiple temperature sensors can be cut using the 500’s ability to switch between up to six sensor inputs with its multi-input option. All input types contained in the 500 (thermocouple or RTD) can be switched, but they must all be of the same type (e.g., Type K Thermocouple).
- A miniature rotary switch, accessible at the front lens, allows convenient switching between inputs. Sensor hook-up is to a snap-on/off terminal block located at the rear of the instrument.
Order Option: Model 500-206 Model 500 Accessories:
- The Rack Adapter Plate permits easy mounting of Model 500 Indicators in standard 19″ instrument racks. Four versions are available for mounting 1, 2, 3 or 4 indicators.
Order Accessory:
- RKS1 for 1 cutout
- RKS2 for 2 cutouts
- RKS3 for 3 cutouts
- RKS4 for 4 cutouts
Model 500 General Specifications | |
---|---|
Repeatability: | 11 Count |
Stability with Temperature: | Zero, 1uV/°C; Span, 0.01%rdg/°C; Thermocouple Reference Junction, internal, automatic, 0.03°C/°C, 5° to 45 °C |
Break Detection: | upscale, approx. 50nA |
Stability with Time: | 1°/year |
Noise Rejection: | NMRR, 60dB @50/60Hz, +/-0.1Hz; CMRR, 120 dB @ 50/60Hz, +/-0.1Hz with 250 ohm unbalance |
Overload Protection: | power lead to ground, 1500 VDC or VAC RMS; across inputs, thermocouple model, T/C up to 250 VDC or VAC for 1 minute, V+ to V-; RTD up to 62 VDC or VAC for 1 minute, V+ to I- |
Input Impedance, Thermocouple: | 20M-Ohms, exclusive of break detect current effects |
Input Impedance, RTD: | 16.9k-Ohms, V+ input; 16.9k-Ohms, I input |
RTD Leadwire Error: | at 150 uA excitation current; 40 milliohms per ohm of equal resistance in V+ and V- leads, 1 Ohm per ohm of unbalance in V+ and V- leads |
Point Update Rate: | 2 per second nominal, 1° readings; 1 per second nominal, 0.1° readings |
Display: | 7-segment red/orange LED, 0.56"H (14.2mm) |
Environmental Ranges: | operating, 5° to 45°C; storage, -40° to +65°C; humidity, </+80%RH non-condensing |
Multi-Input Option Accuracy: | add +/-0.5°C/+/-1°F to instrument accuracy specification |
Alarm Relay Contact Rating: | 0.5A @ 120VAC (non-inductive load) Form C |
Case Construction: | one piece black plastic |
Installation: | secured to panel by U-channel bracket supplied with indicator |
Size: | case, 1.57"H x 3.54"W x 5.35"D (40mm x 90 mm x 136mm); bezel 1.89"H x 3.78"W (48mm x 96mm); panel cutout, 1.77"H x 3.62"W (45mm x 92mm) |
Weight: | 1 lb. (454 grams) |
Power: | 115/230 VAC +/-10%, 50-60Hz |
Warranty: | 1 year |
Model 500 Ordering Guide
Base Model | Base Configuration |
---|---|
Model 500 | 500 Meter, 115/230 VAC power, Type K, °F |
-ALM | Alarm Option |
-206 | 6 Channel Selector |
-RSK 1 cutout | 19" Rack Adapter for 1 Indicator |
-RSK 2 cutouts | 19" Rack Adapter for 2 Indicators |
-RSK 3 cutouts | 19" Rack Adapter for 3 Indicators |
-RSK 4 cutouts | 19" Rack Adapter for 4 Indicators |
- TC Types (K, J)
- (2) Inputs
- Resolution from 0.1 to 1.0
- Switch to °F or °C
- Hold display values
- Begin or end min-max data storage (Rec)
- View or scan T1, T2 or T1 minus T2
- View stored data
- Scan stored data
Each of the “One-Touch” keys on the Model 819 and Model 820 activates a single specific function. You don’t need to turn these off and back on again to change functions, nor do you have to hold two keys simultaneously and hope the function changes. The large-sized keys are easily operated by someone wearing work gloves. The big, five-digit display lets you read the full range of TC types and still have 0.1° resolution. Repeat operations are easy too, since the functions you select are retained even after you shut off the thermometer; you don’t have to reprogram each time you turn one on.
“One-Touch” keys permit:
- Change TC types (Model 819 – J/K/T or Model 820 – J/K)
- Change resolution from 0.1° to 1.0°
- Switch to F or C
- Hold display values
On 820, “One-Touch” keys permit:
- Begin or end min-max data storage (Rec)
- View or scan T1, T2 or T1 minus T2
- View stored data
- Scan stored data
- Exceptional Accuracy: 0.1% with 0.1° resolution F and C
- Repeatability 0.2° typical
- 6 Data storing registers (Model 820)
- Exclusive trend indicators on Model 820 show, rising, falling, or stable temperature at a glance.
- Annunciators display ststus of all functions
- Self-diagnostics show low battery, open TC’s, temperature overrange, or internal hardware faults.
- Drop-proof, dust-proof, and splash-proof ABS case.
- TC Types (K, J)
- (1) Inputs
- Resolution from 0.1 to 1.0
- Switch to °F or °C
- Hold display values
Each of the “One-Touch” keys on the Model 819 and Model 820 activates a single specific function. You don’t need to turn these off and back on again to change functions, nor do you have to hold two keys simultaneously and hope the function changes. The large-sized keys are easily operated by someone wearing work gloves. The big, five-digit display lets you read the full range of TC types and still have 0.1° resolution. Repeat operations are easy too, since the functions you select are retained even after you shut off the thermometer; you don’t have to reprogram each time you turn one on.
“One-Touch” keys permit:
- Change TC types (Model 819 – J/K/T or Model 820 – J/K)
- Change resolution from 0.1° to 1.0°
- Switch to F or C
- Hold display values
On 820, “One-Touch” keys permit:
- Begin or end min-max data storage (Rec)
- View or scan T1, T2 or T1 minus T2
- View stored data
- Scan stored data
- Exceptional Accuracy: 0.1% with 0.1° resolution F and C
- Repeatability 0.2° typical
- 6 Data storing registers (Model 820)
- Exclusive trend indicators on Model 820 show, rising, falling, or stable temperature at a glance.
- Annunciators display ststus of all functions
- Self-diagnostics show low battery, open TC’s, temperature overrange, or internal hardware faults.
- Drop-proof, dust-proof, and splash-proof ABS case.
SPECIFICATIONS | |||||
---|---|---|---|---|---|
ACCESSORIES SUPPLIED: | Integral tilt stand/handle, wrist strap, 9V battery, user manual, two probes with Model 820 (one probe with Model 819). | ||||
ACCURACY: | +/- (0.1% rdg + 0.6°C) | RESOLUTION: | 0.1/1.0°F or C | ||
REPEATABILITY: | +/- 0.2°C typical for 1 week at constant ambient temperature | ||||
THERMOCOUPLES: | RANGE °F °C | TYPE K -328 to 2502 -200 to 1372 | TYPE J -346 to 1400 -210 to 760 | TYPE T -328 to 752 -200 to 400 | |
DISPLAY: | 5-digit LCD 0.4" high. Polarity indication, and decimal point. | ||||
DIMENSIONS: | 7" x 2.9" x 1.1". Net Weight 10 oz. | ||||
ACCESSORIES AVAILABLE: | 8204 1104 8668 | rubber boot leather case vinyl case |
|||
INPUT CURRENT: | 50 nA typical | ||||
READING RATE: | 1 reading/second typical |
HANDHELD CALIBRATOR/INDICATOR Model 845
The 845, the industry's price/performance leader, puts tab-quality calibration and high-performance thermometry in the palm of your hand. Providing 0.5°F accuracy for base metal thermocouple types and 1.7°F accuracy for high temperature thermocouple types and full range resolution of 0.1° in F and C, these instruments are superior for simulating and reading temperatures. Big, "One-Touch" keys let you quickly program every function for both calibrator and thermometer. Use the keypad to select TC types (up to 11 on some models). RTD and Ohms functions, calibrator or thermometer mode, 8F or °C, view 10 memory locations or hold the thermometer reading. The big, bright 5-digit LCD shows all active functions and there are no dials, switches or ramp keyboards to contend with. Calibrator set points can be programmed from an outside source through the thermometer memory mode or direct via the calculator-style keypad. A step function allows one touch output of programmed values, and when turned off, the units retain last-programmed values for quick repeat use. The thermometer mode provides accurate, dependable readings. Ten memory locations let you store temperature measurements for later review.
-
- Model 845 Calibrator/Indicator
- Direct keypad selection of 11 most common TC types.
- NIST Traceable Certificate of Calibration from Manufacturer.
- Shirt pocket size drop-proof, splash-proof and dust-proof case.
SPECIFICATIONS | ||||||
---|---|---|---|---|---|---|
ACCESSORIES SUPPLIED: | NIST traceable certification form manufacturer, universal calibration adapter & cable, integral tilt stand/hangar, wrist strap, 9V battery, and manual. | |||||
ACCURACY: K,J,T,E,N -50°F to Upper Limit | +/- 0.5°F (0.02% Full Scale) | RESOLUTION: | 0.1/1.0°F or C | |||
ACCURACY: K,J,T,E,N <-50°F | +/- 0.5°F (0.02% Full Scale) | |||||
THERMOCOUPLES: | RANGE °F °C | TYPE K -328 to 2502 -200 to 1372 | TYPE J -346 to 1400 -210 to 760 | TYPE T -328 to 752 -200 to 400 | TYPE E -382 to 1832 -230 to 1000 | TYPE N -328 to 2372 -200 to 1300 |
DISPLAY: | 5-digit LCD 0.4" height and decimal point. | |||||
DIMENSIONS: | 7.0" x 2.9" x 1.1". Net Weight 12 oz. | |||||
ACCESSORIES AVAILABLE: | 8204 1104 8668 80010 | rubber boot leather case vinyl case AC Adapter/Battery Charger w/Rechargeable Battery |
||||
INPUT CURRENT: (Thermometer Mode | 50 nA typical | |||||
READING RATE: (Thermometer Mode) | 1 reading/second typical | |||||
THERMOCOUPLES: | RANGE °F °C | TYPE B 932 to 3308 500 to 1820 | TYPE R 32 to 3214 0 to 1768 | TYPE S 32 to 3214 0 to 1768 | TYPE C/D 32 to 4201 0 to 2316 | TYPE G 572 to 4201 300 to 2316 |
ACCURACY: B,R,S,G,C,D | +/- 1.7°F |