Products
Thermocouple Wire - Thermocouple Wire Constructions
Constructions are arrangements of the conductor and insulation that suit the application. For instance, singles can be used to wire panels more easily than a jacketed construction. And duplex constructions can be more easily used in conduits. And twisted duplex constructions are more flexible than paralleled ones and counteract flux induced noises. Twisted and shielded constructions provide the best noise reduction.
CONSTRUCTIONS |
|
Code |
Descriptions |
1 |
Insulated
Single Conductor |
3 |
Insulated
Duplex Conductors - Ripcord |
4 |
Insulated
Duplex Conductors - Paralleled with Overall Insulation Jacket |
7 |
Insulated
Duplex Conductors - Twisted |
8 |
Insulated
Duplex Conductors - Twisted with Overall Insulation Jacket |
9 |
Insulated
Duplex Conductors - Twisted with Mylar-backed Aluminum Shield,
Drain Wire, and Overall Insulation Jacket |
Protective metal overbraids are used to enhance abrasion and cut-through resistance. With an approximately 85% coverage they also provide a noise shield although not as effective as the aluminized mylar tape full coverage shields.
PROTECTIVE
OVERBRAID |
SS
Flex Tubing |
|||
Code |
Descriptions |
Code |
I.D. |
Approx.
O.D. |
0 |
No
Attendant |
FT-125 |
0.125" |
0.200" |
FT-187 |
0.187" |
0.280" |
||
1 |
Stainless
Steel 1400°F (760°C) Wire Braided over Insulated Construction |
FT-250 |
0.250" |
0.340" |
2 |
Inconel
Wire 1800°F (982°C) Braided over Insulated Construction |
FT-312 |
0.310" |
0.420" |